Note: You are seeing this text-only version of our site because you are using an older browser that is not standards-compliant.
How to upgrade to a FREE standards-compliant browser.
Some Netscape 7 and Mozilla users may see this warning in error. Click here to fix the problem.

Modbus Organization

Advantages of Joining | Join Form | Toolkit | Subscribe to Newsletter

Text Size: smallmediumlarge
 Back to Company Directory

Real Time Automation

Member: Yes

Address:

150 S Sunnyslope Rd, Ste 130
Brookfield, WI 53005 USA

Phone: +1 262-439-4999
Fax: +1 262-439-4989
Web Site: www.rtaautomation.com
Contact: John Rinaldi
Email: ascii2plc@rtaautomation.com

Description:

Real Time Automation delivers easy to use, simple to maintain networking solutions. Whether you need an off the shelf gateway to move data between different networks, a daughter card to network enable a serial device, or source code to add to your embedded processors - Real Time Automation is here to help. Our simple solutions and industry leading support are guaranteed to save you time, money and headaches. You get support from an engineer who developed the product and a product made in the USA that is always stocked. With RTA you can take a solution from discovered to implemented in a day. RTA's team of leading automation engineers has a proven track record of delivering on time, on budget, and to conformance standards, with its vast working knowledge of Modbus TCP, Modbus RTU, DeviceNet, EtherNet/IP, LonWorks, PROFINET IO, Profibus, AS Interface, CANopen, and BACnet.

 

Product Name Type Connectivity Product Description
Modbus TCP Source Code, 495MTC or 495MTSSoftware - ProgrammingModbus TCPQuickly and easily add Modbus TCP communications to your products with the Real Time Automation Modbus TCP Client/Server and development kits. Developed specifically for industrial platforms and fully integrated with any number of RTOS systems and TCP/IP stacks, you can have Modbus TCP communications in days not weeks, months or years. The development kit includes everything you need to implement your Modbus TCP networking solution; "no royalty," single task source code, sample objects, PC Tools, a ready-to-run sample application, complete documentation and much more.
Exlink PCB Gateway, 6102-EXNetwork GatewayModbus, Modbus TCP/IPWith a high-speed TTL serial interface (230 Kbps), extremely small footprint and high performance 10/100 Mb network interface, the 6102-EX Ethernet board level gateway is a great option for quickly adding EtherNet/IP and Modbus TCP communications to your standard product line. Based on a very powerful 55-Mhz ARM7TDMI RISC core, the 6102 is a simple, powerful and cost-effective solution for Ethernet networking.
Modbus RTU Slave to Modbus TCP Client Gateway, 460MSMMNetwork GatewayModbus, Modbus TCPThe 460MSMM moves data between up to 31 Modbus RTU Slave devices and a Modbus TCP Client. Directly map Modbus RTU registers and Coil data to Modbus TCP network.
Modbus RTU Slave to BACnet/IP Client Gateway, 460MMBSNetwork GatewayModbus RTUThe 460MMBS moves data between up to 31 Modbus RTU Slave devices and a BACnet/IP Client. Directly map Modbus RTU register and coil data to BACnet/IP network.
Modbus RTU Slave to DeviceNet Master Gateway, 460MMDSNetwork GatewayModbus RTUMaster. Directly map Modbus RTU Register and Coil data to a DeviceNet network.
Modbus RTU Slave to ASCII Device Gateway, 460MMANetwork GatewayModbus RTUThe 460MMA moves data between up to 31 Modbus RTU Slave devices and an ASCII device. Directly map Modbus RTU Register and Coil data to an ASCII device.
Modbus RTU Slave to Allen-Bradley PLC Gateway, 460ETCMMNetwork GatewayModbus RTUThe 460ETCMM moves data between up to 32 Modbus RTU Slave devices and up to 5 different Allen-Bradley PLC's. Directly map Modbus RTU Slave data and user defined Tags or Registers in the data table of your Allen-Bradley PLC.
Modbus RTU Slave to Ethernet TCP/IP Gateway, 460MMTCPNetwork GatewayModbus RTUThe 460MMTCP moves data between up to 31 Modbus RTU Slave devices and an ASCII device. Directly map Modbus RTU Register and Coil data to an Ethernet TCP/IP device.
Modbus RTU Slave to BACnet MS/TP Gateway, 460MMBMSNetwork GatewayModbus RTUThe 460MMBMS moves data between up to 31 Modbus RTU Slave devices and a BACnet MS/TP Master. Directly map Modbus RTU register and coil data to BACnet MS/TP network.
Modbus RTU Slave to Modbus TCP/IP Server Gateway, 460MCMMNetwork GatewayModbus, Modbus TCPThe 460MCMM moves data between up to 31 Modbus RTU Slave devices and a Modbus TCP Server. Directly map Modbus RTU register and coil data to Modbus TCP network.
Modbus RTU Slave to EtherNet/IP Scanner Gateway, 460ESMMNetwork GatewayModbus RTUThe 460ESMM moves data between up to 31 Modbus RTU Slave devices and an EtherNet/IP Scanner. Directly map Modbus RTU register and coil data to an EtherNet/IP network.
DeviceNet Slave to a Modbus RTU Master Gateway, 460MRSDMNetwork GatewayModbus RTUThe 460MRSDM moves data between up to 31 DeviceNet Slave devices and a Modbus RTU Master. Directly map DeviceNet data to registers and coils in a Modbus RTU Master.
Modbus RTU Master to an EtherNet/IP Scanner Gateway, 460ESMRSNetwork GatewayModbus RTUThe 460ESMRS moves data between a Modbus RTU Master and an EtherNet/IP Scanner. Directly map Modbus RTU Register and Coil data to an EtherNet/IP Scanner
Modbus TCP Server to a Modbus RTU Master Gateway, 460MCMRSNetwork GatewayModbus, Modbus TCPThe 460MCMRS moves data between a Modbus TCP Server and a Modbus RTU Master. Directly map Modbus RTU Register and Coil data to a Modbus TCP Server
Modbus RTU Master to a BACnet/IP Client Gateway, 460MRSBSNetwork GatewayModbus RTUThe 460MRSBS moves data between a Modbus RTU Master and a BACnet/IP Client. Directly map Modbus RTU register and coil data to a BACnet/IP Client.
Modbus RTU Master to a Modbus TCP/IP Client Gateway, 460MSMRSNetwork GatewayModbus, Modbus TCPThe 460MSMRS moves data between a Modbus RTU Master and a Modbus TCP Client. Directly map Modbus RTU Register and Coil data to a Modbus TCP Client.
Modbus RTU Master to ASCII Gateway, 460MRSANetwork GatewayModbus RTUThe 460MRSA moves data between a Modbus RTU Master and your ASCII device. Directly map ASCII data to a Modbus RTU Master.
Modbus RTU Master to EtherNet/IP Adapter Gateway, 460ECMRSNetwork GatewayModbus RTUThe 460ECMRS moves data between a Modbus RTU Master and an EtherNet/IP Adapter. Directly map Modbus RTU Register and Coil data to an EtherNet/IP Adapter.
Modbus RTU Master to DeviceNet Master Gateway, 460MRSDSNetwork GatewayModbus RTUThe 460MRSDS moves data between a Modbus RTU Master and a DeviceNet Master. Directly map Modbus RTU Register and Coil data to a DeviceNet Master.
Modbus RTU Master to Ethernet TCP/IP Gateway, 460MRSTCPNetwork GatewayModbus RTUThe 460MRSTCP moves data between up to 10 Ethernet TCP/IP devices and a Modbus RTU Master. Directly map Ethernet TCP/IP data to Registers and Coils in a Modbus RTU Master.
Modbus RTU Master to Allen-Bradley PLC Gateway, 460ETCMRSNetwork GatewayModbus RTUThe 460ETCMRS moves data between a Modbus RTU Master and an Allen-Bradley PLC. Directly map Modbus RTU data and user-defined Tags or Registers in the data table of your Allen-Bradley PLC.
Modbus TCP/IP Server to BACnet/IP Client Gateway, 460MCBSNetwork GatewayModbus TCPThe 460MCBS moves data between up to 31 Modbus TCP Server devices and a BACnet/IP Client. Directly map Modbus TCP Register and Coil data to a BACnet/IP Client.
Modbus TCP/IP Server to EtherNet/IP Scanner, 460ESMCNetwork GatewayModbus TCPThe 460ESMC moves data between up to 31 Modbus TCP Servers and an EtherNet/IP Scanner. Directly map Modbus TCP Register and Coil data to an EtherNet/IP Scanner.
Modbus TCP/IP Server to ASCII Gateway, 460MCAModbus TCPThe 460MCA moves data between up to 31 Modbus RTU Slave devices and an ASCII device. Directly map Modbus TCP Register and Coil data to an ASCII device.
Modbus TCP/IP Server to Allen-Bradley PLC Gateway, 460ETCMCNetwork GatewayModbus TCPThe 460ETCMC moves data between up to 31 Modbus TCP Server devices and an Allen-Bradley PLC. Directly map Modbus TCP data and user-defined Tags or Registers in the data table of an Allen-Bradley PLC.
Modbus TCP/IP Server to DeviceNet Master Gateway, 460MCDSNetwork GatewayModbus TCPThe 460MCDS moves data between up to 31 Modbus TCP Server devices and a DeviceNet Master. Directly map Modbus TCP Register and Coil data to a DeviceNet network.
Modbus TCP/IP Server to BACnet MS/TP Master Gateway, 460MCBMSNetwork GatewayModbus TCPThe 460MCBMS moves data between up to 31 Modbus TCP Server devices and a BACnet MS/TP Master. Directly map Modbus TCP Register and Coil data to BACnet MS/TP network
Modbus TCP/IP Client to ASCII Gateway, 460MSANetwork GatewayModbus TCPThe 460MSA moves data between a Modbus TCP/IP Client and an ASCII device. Directly map ASCII data to a Modbus TCP Client
DeviceNet Slave to Modbus TCP/IP Client Gateway, 460MSDMNetwork GatewayModbus TCPThe 460MSDM moves data between up to 31 DeviceNet Slave devices and a Modbus TCP Client. Directly map DeviceNet data to Registers and Coils in a Modbus TCP Client
Modbus TCP/IP Client to BACnet/IP Client Gateway, 460MSBSNetwork GatewayModbus TCPThe 460MSBS moves data between a Modbus TCP Client and a BACnet/IP Client. Directly map Modbus RTU Register and Coil data to a BACnet/IP Client
Modbus TCP/IP Client to EtherNet/IP Adapter Gateway, 460ECMSNetwork GatewayModbus TCPThe 460ECMS moves data between a Modbus TCP Client and an EtherNet/IP Adapter. Directly maps Modbus TCP Register and Coil data to an EtherNet/IP Adapter
Modbus TCP/IP Client to Ethernet TCP/IP Gateway, 460MSTCPNetwork GatewayModbus TCPThe 460MSTCP moves data between up to 10 Ethernet TCP/IP devices and a Modbus TCP Client. Directly maps Ethernet TCP/IP data to registers and coils in a Modbus TCP Client
Modbus TCP/IP Client to DeviceNet Master Gateway, 460MSDSNetwork GatewayModbus TCPThe 460MSDS moves data between a Modbus TCP Client and a DeviceNet Master. Directly maps Modbus TCP register and coil data to a DeviceNet Master
Modbus TCP/IP Client to Allen-Bradley PLC Gateway, 460ETCMSNetwork GatewayModbus TCPThe 460ETCMS moves data between a Modbus TCP Client and an Allen-Bradley PLC. Directly maps Modbus TCP data and user defined Tags or Registers in the data table of your Allen-Bradley PLC
Modbus TCP/IP Client to EtherNet/IP Scanner Gateway, 460ESMSNetwork GatewayModbus TCPThe 460ESMS moves data between a Modbus TCP Client and an EtherNet/IP Scanner. Directly map Modbus TCP Register and Coil data to an EtherNet/IP Scanner
Modbus RTU Server to Profinet IO Controller Gateway, 460PSMMNetwork GatewayModbus RTUThe 460PSMM moves data between up to 32 Modbus RTU Server devices and a Profinet IO Controller. With the 460PSMM you make a direct connection between Modbus RTU Server data and user defined Slots in your Profinet IO Controller. The 460PSMM provides an option to access Modbus RTU Server devices without having to upgrade your PLC or get an expensive in rack solution.
Modbus RTU Server to Profibus DP Master Gateway, 460MMPBSNetwork GatewayModbus RTUThe 460MMPBS moves data between up to 32 Modbus RTU Server devices and a Profibus DP enabled PLC. With the 460MMPBS you are making a direct connection between Modbus RTU Server data and user defined Slots in your Profibus DP PLC. The 460MMPBS provides an option to access Modbus RTU Server devices without having to upgrade your PLC or get an expensive in rack solution.
Modbus RTU Client to Profinet IO Controller Gateway, 460PSMRSNetwork GatewayModbus RTUThe 460PSMRS moves data between a Modbus RTU Client device and a Profinet IO Controller. With the 460PSMRS you are making a direct connection between Modbus RTU Client Register and Coil data and user defined Slots in your Profinet IO Controller. The 460PSMRS provides an option to access your Modbus RTU Client device without having to upgrade your PLC or get an expensive in rack solution.
Modbus TCP Server to Profinet IO Controller Gateway, 460PSMCNetwork GatewayModbus TCPThe 460PSMC moves data between up to 32 Modbus TCP/IP Server devices and a Profinet IO Controller. With the 460PSMC you are making a direct connection between Modbus TCP/IP Server data and user defined Slots in your Profinet IO Controller. The 460PSMC provides an option to access Modbus TCP/IP Server devices without having to upgrade your PLC or get an expensive in rack solution.
Modbus TCP Client to Profinet IO Controller Gateway, 460PSMSNetwork GatewayModbus TCPThe 460PSMS moves data between a Modbus TCP/IP Client device and a Profinet IO Controller. With the 460PSMS you are making a direct connection between Modbus TCP/IP Client Register and Coil data and user defined Slots in your Profinet IO Controller. The 460PSMS provides an option to access a Modbus TCP/IP Client device without having to upgrade your PLC or get an expensive in rack solution.