Modbus Organization

Advantages of Joining | Join Form | Toolkit | Subscribe to Newsletter

Text Size: smallmediumlarge
 Back to Company

 

SAUTER

modu524/525+721

Type:  Controller
Description:  The modu524/525 automation stations (AS) are used to regulate, control, monitor and optimise operational installations. They are based entirely on BACnet/IP communication. A web server (modu-Web) is integrated into the AS for comprehensive operation, direct visualisation of the data points, notification and forwarding of alarms and creation of time profiles (scheduler). The moduCom communication module modu721 is used to extend the modu524 and modu525 automation stations. It is used to integrate third-party products on the automation level in operational systems such as HVAC engineering. Third-party products based on the field bus protocols for EIA-232 or EIA-485 such as Modbus/RTU, M-Bus can be integrated in the automation station. This allows for the option of BACnet/IP communication with the management level.
Connectivity:  Modbus RTU
Features:  Part of the SAUTER modulo 5 system family; modu524/525: Modular automation station (AS); Regulation, control, monitoring and optimisation of operational systems, e.g. in HVAC engineering; 26 inputs/outputs; Expandable with up to 3 modules (modu524) or 8 modules (modu525); BACnet/IP communication (EN ISO 16484-5); BACnet profile B-BC; AMEV profile AS-B; Integrated web server; Programming/parameterisation via PC using CASE Suite (based on IEC 61131-3); Control libraries; Time and calendar function; Predictive control based on meteorological forecast data; Data recording; Can be equipped with local operating and indicating units, located up to 10 m away; Alive signal output pulsed:: modu721: One or two COM modules per AS; Connection to non-SAUTER systems (PLC, chillers, meters etc.); Connection for point-to-point protocols with EIA-232 interface; Connection for field bus protocols based on EIA-485; 2-wire EIA-485 (half-duplex); Galvanic isolation up to 300 V; Jumper for EIA-485 bus voltage, bus termination and connection for galvanic isolation; M-Bus and further integration of third-party products with the AS for integrated control and optimised; regulation and the option to use BACnet/IP communication with the management level; Direct labelling on the front
Specifications:  COM port, EIA-232 (DTE) D-Sub plug (9-pin, male); COM port, EIA-485 6 screw terminals (2 × C, 2 × D+, 2 × D-); Baud rate 0.3...57.6 kbit/s; Data bits 5, 6, 7, 8; Stop bits 1, 1.5, 2; Parity None, even, odd; Modbus function: As master only; Range of slave addresses 1...247; Max. 200 objects/data points; Multi-telegram addressable; Telegram transmission only as RTU frame (Remote Terminal Unit frame); FC01-06, 15, 16